Among the many LED controllers of Magic Lamp, T-500K_MADRIX 3 is a very popular product. This kind of controller is usually used for decoration of large-scale places, so most people may not understand it very well. Today we will get a general idea of its basic parameters.
1. Computer-side settings:
1. Install MADRIX_Full_Install 3.6F version of the software and related plug-ins.
2. Software supports automatic search function.
3. Setting up IP address on computer side:
IP: 192.168.60.178
Subnet mask: 255.0.0.0
Gateway: Empty
2. Controller side settings:
1. The controller can set the number of units loaded on each port by dialing.
Controller Dial Switch Settings:
Dial switch
state
Explain
No. 8
Dial up
On-board DMX chip
Dial down
On-board UCS1903 chip
Bit 6,7
Dial up and dial up
Each port carries one unit.
Dial down and dial up
Each port carries two units
Dial up and dial down
Each port carries three units
Number 5-1
Dial up Representation 0
Combine 5-bit binary coding to set the controller ID number.
Dial up Representative 1
2. As long as the controller dials the IP address and the number of port loaded units, the computer supports automatic search.
Example: Each port carries three units:
Controller Dialing
Controller IP
Port (Univers)
001
192.168.10
1-24
002
192.168.11
25-48
003
192.168.12
49-72
004
192.168.13
73-96
005
192.168.14
97-120
...
...
...
It should be noted that when using MADRIX in Germany, the 'Post Sync' option in 'Sync' must be set in order to send 'synchronization commands' to the computer.