Description of Magic Lamp T-500K_MADRIX 3
Date:
2019-09-02

Among the many LED controllers of Magic Lamp, T-500K_MADRIX 3 is a very popular product. This kind of controller is usually used for decoration of large-scale places, so most people may not understand it very well. Today we will get a general idea of its basic parameters.


1. Computer-side settings:

1. Install MADRIX_Full_Install 3.6F version of the software and related plug-ins.

2. Software supports automatic search function.

3. Setting up IP address on computer side:

IP: 192.168.60.178

Subnet mask: 255.0.0.0

Gateway: Empty


2. Controller side settings:


1. The controller can set the number of units loaded on each port by dialing.


Controller Dial Switch Settings:


Dial switch

state

Explain

No. 8

Dial up

On-board DMX chip

Dial down

On-board UCS1903 chip

Bit 6,7

Dial up and dial up

Each port carries one unit.

Dial down and dial up

Each port carries two units

Dial up and dial down

Each port carries three units

Number 5-1

Dial up Representation 0

Combine 5-bit binary coding to set the controller ID number.

Dial up Representative 1

2. As long as the controller dials the IP address and the number of port loaded units, the computer supports automatic search.


Example: Each port carries three units:


Controller Dialing

Controller IP

Port (Univers)

001

192.168.10

1-24

002

192.168.11

25-48

003

192.168.12

49-72

004

192.168.13

73-96

005

192.168.14

97-120

...

...

...

It should be noted that when using MADRIX in Germany, the 'Post Sync' option in 'Sync' must be set in order to send 'synchronization commands' to the computer.